Add to Cart
Universal Dynasonic Portable Digital Hardness Tester Supports UCI and LEEB Testing Methods
Product Introduction:
At present, there are kinds of methods for hardness measurement, commonly used like Brinell, Rockwell, Vickers, Leeb, etc, while the disadvantages are obvious for above hardness measurement methods.
Rockwell and Brinell with heavy loading force and big indentation, lead to serious destructive on sample surface.
Vickers apply optical measurement, but only professional technicians can smoothly operate, impossible to measure hardness of heavy work piece, installed machinery and permanently assembled parts.
Leeb hardness tester apply rebound and indirect method to measure hardness, easily lead to big deviation when convert to Birnell, Rockwell and Vickers scales.
SU-200 is a combined portable hardness tester which integrated the ultrasonic hardness testing method and dynamic Leeb hardness testing resolution in one instrument.
SU-200 is updated product based on ultrasonic hardness tester SU-100 and Leeb hardness tester SH-500, it has full of functions of SU-100 and SH-500, so it supports all of static ultrasonic measuring probes and Leeb dynamic impact devices together.
UCI method apply ultrasonic contact impedance method to do comparative hardness measurement for testing pieces, with advantages of high accuracy, efficiency, portable and easy operation.
Widely used to measure hardness of small forgings, cast material, weld inspection, heat affected zone, Ion-nitrided stamping dies and molds, forms, presses, thin walled parts, bearings, tooth flanks, etc.
Leeb method is a dynamic hardness test method using a calibrated instrument that impacts a spherically shaped carbide ball or diamond tipped body with a fixed velocity(generated by a spring force) onto a surface of the material under test. The ratio of the rebound velocity to the impact velocity of the impact body is a measure of the hardness of the material under test.
Leeb method used to test hardness of Die cavity of molds, Bearings and other parts, Failure analysis of pressure vessel, steam generator and other equipment, Heavy work piece, The installed machinery and permanently assembled parts,Testing surface of a small hollow space, Material identification in the warehouse of metallic materials, Rapid testing in large range and multi-measuring areas for large-scale work piece.
Specifications Data:
Product Name |
Dynasonic Hardness Tester |
Model |
SU-200 |
Code# |
#882-131 |
Loading Force |
2Kgf(Optional: 1Kgf, 5Kgf, 10Kgf) |
Impact Device |
Standard: D (Optional: DC/D+15/DL/G/C/E) |
Measuring Range |
HRC:20.3~68; HRB:41~100; HRA:61~85.6; HV:80~15999; HB:76~618; HLD 170-960;Mpa 255~2180N/mm2 |
Measuring Accuracy |
HV:±3%HV; HRC:±1.5HRC; HB:±3%HB:HL:±3%HL |
Indenter |
136°Vickers Diamond Indenter |
Measuring Direction |
Support 360° |
Data Storage |
To save 1000-groups of measuring data and 20-groups of calibration data |
Hardness Scale |
HV,HB,HRC,HRA,HRB,MPa |
Data display |
Loading force,Testing-times, Testing result, Average, Maximum,Minimum,Deviation and Conversion scale. |
Hardness Indication |
LCD display |
Operating Environment |
Temperature:-10℃~50℃; Humidity: 30%~80%R.H |
Operating Voltage |
DC 4.2V |
Instrument Dimensions |
160x80x31mm |
Net Weight |
Approximate 500g(Without probe) |
Standard Delivery:
Product Name |
Order # |
Product Name |
Order # |
Instrument Main Body |
882-131 |
Probe Silicone Cap |
882-711 |
2Kgf manual Probe HP-2k |
882-321 |
Instrument Manual |
SU-200 |
Impact Device Type D |
882-410 |
Accessories Box |
882-901 |
Probe Cable |
882-801 |
Certificate |
SU-200 |
USB Cable |
882-851 |
Leeb hardness Block |
|
Manual Probes Specifications:
Probe Type |
HP-1K |
HP-2K |
HP-5K |
HP-10K |
Code# |
882-311 |
882-321 |
882-331 |
882-341 |
Remark |
Optional |
Standard |
Optional |
Optional |
Loading force |
10N |
20N |
50N |
98N |
Diameter |
22mm |
22mm |
22mm |
22mm |
Length |
154mm |
154mm |
154mm |
154mm |
Oscillating Rod Diameter |
2.4mm |
2.4mm |
3mm |
3mm |
Roughness of measuring surface |
Ra<3.2um |
Ra<5um |
Ra<10um |
Ra<15um |
Min weight of test material |
0.3kg |
0.3kg |
0.3kg |
0.3kg |
Min thickness of test material |
2mm |
2mm |
2mm |
2mm |
Motorized Probes Specifications:
Probe Type |
MP-100 |
MP-300 |
MP-500 |
MP-800 |
Code# |
882-211 |
882-221 |
882-231 |
882-241 |
Remark |
Optional |
Optional |
Optional |
Optional |
Loading force |
1N |
3N |
5N |
8N |
Diameter |
46mm |
46mm |
46mm |
46mm |
Length |
200mm |
200mm |
200mm |
200mm |
Oscillating Rod Diameter |
3.7mm |
3.7mm |
3.7mm |
3.7mm |
Min weight of test material |
0.3kg |
0.3kg |
0.3kg |
0.3kg |
Min thickness of test material |
2mm |
2mm |
2mm |
2mm |
Leeb Impact Device Specification:
Type of impact device |
DC(D)/DL |
D+15 |
C |
G |
E |
|||||
Impacting energy Mass of impact body |
11mJ 5.5g/7.2g |
11mJ 7.8g |
2.7mJ 3.0g |
90mJ 20.0g |
11mJ 5.5g |
|||||
Test tip hardness: Dia. Test tip: Material of test tip: |
1600HV 3mm Tungsten carbide |
1600HV 3mm Tungsten carbide |
1600HV 3mm Tungsten carbide |
1600HV 5mm Tungsten carbide |
5000HV 3mm synthetic diamond |
|||||
Impact device diameter: Impact device length: Impact device weight: |
20mm 86(147) /75mm 50g |
20mm 162mm 80g |
20mm 141mm 75g |
30mm 254mm 250g |
20mm 155mm 80g |
|||||
Max. hardness of sample |
940HV |
940HV |
1000HV |
650HB |
1200HV |
|||||
Mean roughness value of sample surface Ra: |
1.6μm |
1.6μm |
0.4μm |
6.3μm |
1.6μm |
|||||
Min. weight of sample: Measure directly Need support firmly Need coupling tightly |
>5kg 2~5kg 0.05~2kg |
>5kg 2~5kg 0.05~2kg |
>1.5kg 0.5~1.5kg 0.02~0.5kg |
>15kg 5~15kg 0.5~5kg |
>5kg 2~5kg 0.05~2kg |
|||||
Min. thickness of sample Coupling tightly Min. layer thickness for surface hardening |
5mm
≥0.8mm |
5mm
≥0.8mm |
1mm
≥0.2mm |
10mm
≥1.2mm |
5mm
≥0.8mm |
|||||
Size of tip indentation:
|
||||||||||
Hardness 300HV |
Indentation diameter Depth of indentation |
0.54mm
24μm |
0.54mm
24μm |
0.38mm
12μm |
1.03mm
53μm |
0.54mm
24μm |
||||
Hardness 600HV |
Indentation diameter Depth of indentation |
0.54mm
17μm |
0.54mm
17μm |
0.32mm
8μm |
0.90mm
41μm |
0.54mm
17μm |
||||
Hardness 800HV |
Indentation diameter Depth of indentation |
0.35mm
10μm |
0.35mm
10μm |
0.35mm
7μm |
--
-- |
0.35mm
10μm |
||||
Available type of impact device |
DC: Test hole or hollow cylindrical; DL: Test slender narrow groove or hole |
D+15: Test groove or reentrant surface |
C: Test small, light, thin parts and surface of hardened layer |
G: Test large, thick, heavy and rough surface steel |
E: Test super high hardness material |